Water Oil Separators (WOS) have been developed to separate lubricant oil from condensate gathered in the Compressed Air Systems. WOS Water Oil Separators can be used in a variety of applications. For applications not listed please contact the producer or your local distributor.

Quick info

Description

Designed for high demand operations

Water Oil Separators (WOS) have been developed to separate lubricant oil from condensate gathered in the Compressed Air Systems. WOS Water Oil Separators can be used in a variety of applications. For applications not listed please contact the producer or your local distributor.

Main Features

Small compact design

Easy to maintain

Can handle and separate any type of oil.

Works with any type of condensate drain

Simple to install

No complex sizing required

Specifications

FILTER HOUSING SPECIFICATIONS:​

OPERATING TEMPERATURE
OPERATING MEDIA
RESIDUAL OIL CONTENT
SERVICE INTERVAL
1.5 – 45 °C (max 65 °C)(1)
35 – 113 °F (max. 149 °F) (2)
Condensate (air, water, oil); Non aggressive;
Not suitable for emulsion
< 10ppm
When first of following parameters appears:
– 4000 operating hours of compressor (4)
– 12 months regardless of compressor operating hours
– outlet oil concentration reaches concentration determined with local diresctive

COMPLETE UNIT SPECIFICATIONS:​

MODEL
TECHNICAL DATA
COLD CLIMATE ZONE
15 °C 60 %RH
MILD CLIMATE ZONE
25 °C 60 % RH
HOT CLIMATE ZONE
40 °C 100 %RH
DIMENSIONS
A (MM)
DIMENSIONS
B (MM)
DIMENSIONS
C (MM)
WOS-4
Max oil adsorption [kg]
Max FAD [Nm/min3]/[scfm]
Max condensate flow [l/h]
2.89
4.82/170
2.33
2.43
4.04/142
.4
1.23
2.05/72.3
6.3
416
243
411
WOS-8
Max oil adsorption [kg]
Max FAD [Nm/min3]/[scfm]
Max condensate flow [l/h]
6.01
10.0/353
4.77
5.04
8.4/296
.1
2.55
4.25/150
13.1
730
343
680
WOS-20
Max oil adsorption [kg]
Max FAD [Nm/min3]/[scfm]
Max condensate flow [l/h]
14.64
24.4/861
11.4
12.28
20.5/723
17.2
6.22
10.37/366
32.0
820
366
940
WOS-35
Max oil adsorption [kg]
Max FAD [Nm/min3]/[scfm]
Max condensate flow [l/h]
25.4
42.3/1495
19.8
21.311
35.5/1254
29.8
0.9
17.99/635
55.6
960
386
137

Features

Oil Residue

Oil residue value is less than 10 ppm.

Test Valve

Test valve and test set included for sampling purposes

Condensate Settling Tank

No condensate settling tank is required (therefore there is no bacteria build up)

Clean Water Outlet

Residual oil content <10ppm

Activated Carbon Filter Cartridge

Final oil elimination

Water Quality Test

Water Quality Test should be performed at least once per month, to control the contamination level of disposed condensate. If oil concentration is reached. Oil Filter Cartridges must be changed.